Media Water; water-oil emulsions; synthetic oil; aggressive media; hydraulic oil; compressed air Pressures: Standard: 0 to 350 bar (Up to a max. 800 bar.) Please contact us regarding any special requirements outside our standard range. Nominal diameters: DN 3 to DN 250 . Please contact us if you have special requirements outside our standard range.
|
Typical Fields of Application: - Hydraulic controls
- Pipe-testing equipment
- Roll-balancing systems
- Descaling plants
- And many more
Temperatures: - Max. operating temperature: 70°C
- Max. ambient temperature: 60°C
|
| 2/2-way directional valves, cartridge type block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.: DN 16 to DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar Opening pressure: 2,5 bar
|

|
| 2/2-way directional valves, cartridge type with cover, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 16 to DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar Opening pressure: 2,5 bar
|

|
| 2/2-way directional check valves, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.: DN 16 to DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar Opening pressure: 4) 2,5 bar
|

|
| 2/2-way directional check valves with cover, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 16 to DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar Opening pressure: 4) 2,5 bar
|

|
| Pilot-operated check valves, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.: DN 16 to DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar Opening pressure: 4) 2,5 bar
|

|
| Pilot-operated check valves with cover, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 16 to DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar Opening pressure: 4) 2,5 bar
|

|
| Pilot-operated pressure relief valves with cover, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 16 to DN 32 (other diam. on request) Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar Pressure setting: 4) 15 to 350 bar
|

|
| Directly controlled pressure relief valves with cover, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 16 to DN 32 (other diam. on request) Pressure setting:4) 15 to 350 bar
|

|
| Proportional pressure reducing valve, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 16 to DN 32 (other diam. on request) Pressure setting:4) 15 to 350 bar
|
|
| Pilot-operated pressure reducing valves with cover, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 16 to DN 32 (other diam. on request) Pressure setting:4) 15 to 350 bar
|

|
| Pressure-reducing valve, directly operated, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 16 to DN 32 (other diam. on request) Pressure setting:4) 15 to 350 bar
|

|
| Proportional pressure reducing valve, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 16 to DN 32 (other diam. on request) Pressure setting:4) 15 to 350 bar
|

|
| 2/2-way directional valves, cartridge type, with cover and pilot valve, block-mounted; normally open |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.: 1) : DN 16 to DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar Voltage: 3) 24 V DC
|

|
| 2/2-way directional valves, cartridge type, with cover and pilot valve block-mounted; normally closed |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.: DN 16 to DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar
Voltage: 3) 24 V DC
|

|
| 3/2-way directional pilot valves, directly controlled, panel-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.: DN 6, DN 10 Max. operating pressure: 350 bar (400 bar) Voltage: 3) 24 V DC Input: 31 W, 55 W
|

|
| 3/2-way directional pilot valves, pneumatically controlled, panel-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Control media: Air (24 V DC, 8 W) Nom. dia: DN 16, DN 25 Max. operating pressure: 350 bar (400 bar)
|

|
| Valves, panel-mounted or as single valves |
|
|

Directional valves (2/2 way; 3/2 way; 4/2 way; 4/3 way; ...) shut-off, pressure, flow or power regulating functions Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 6 to DN 50 Max. operating pressure: 350 bar
|

|
| Pressure-compensated manual shut-off valves, valve spindle carried in ball bearing, with or without electrical/visual position indicator, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia:1) DN 16 to DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar
|
|
| Motor operated shut-off valves with electrical/visual position indicator, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 50 to DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar
|
|
| Accumulator shut-off valves with or without mechanical locking feature, with or without electrical/visual position indicator, block-mounted |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nominal diameters:1) DN 40 bis DN 250 Mounting: To DIN 24342 (DN 16 to DN 100) Max. operating pressure: 350 bar
|
|
| Descaling valves |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:2) DN 32 to DN 250 Max. operating pressure:4) 350 bar Voltage:3) 24 V DC
|
|
| Accumulator shut-off valve /Descaling valve combinations |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 32 to DN 250 Max. operating pressure: 350 bar
|
|
| Valve blocks for your specific requirements |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia.:1) DN 16 to DN 250 Max. operating pressure: 350 bar (400 bar)
|
|
| 2/2-way inline valves |
|
|

Media: Water, water-oil emulsions, hydraulic fluid, aggressive media Nom. dia: DN 50 to DN 300 Opening pressure:4) 2,5 bar Voltage:3) 24 V DC
|
|
| Pump unloading valves |
|
|

Media: water; water-oil emulsions Nominal diameters: DN 20 to DN 63 Opening pressure:4) 400 bar Voltage:3) 24 V DC
|
|
1) On the basic of a tailored body design, these valves can be adapted to a given mounting configuration.
2) Various control capabilities and a tailored body design allow these valves to be adapted to any given configuration.3) Other voltages on request.4) Other pressure ratings on request.

|